| Test Method |
SCCH
|
CCT
|
WITT
|
DUST
|
Notes
|
| American Society for Testing and Materials | |||||
| ASTM B 117 Salt Fog |
X
|
X
|
-
|
-
|
|
| ASTM B 368 CASS-Copper Accelerated Salt Fog |
X
|
-
|
-
|
-
|
w/Cass Solution Valve |
| ASTM B 380 Corrodkote w/Condensing RH |
X
|
-
|
-
|
-
|
w/RH Accessory Package |
| ASTM D 870 Water Immersion |
-
|
-
|
X
|
-
|
|
| ASTM D 1735 Fogging RH |
X
|
X
|
-
|
-
|
|
| ASTM D 2247 Condensing RH |
X
|
-
|
-
|
-
|
w/RH Accessory Package |
| ASTM G 85 A1 Acetic Acid Salt Fog |
X
|
-
|
-
|
-
|
w/Cass Solution Valve |
| ASTM G 85 A2 Cyclic Acidified Salt Fog |
X
|
-
|
-
|
-
|
Multi-Test Control Package Required |
| ASTM G 85 A3 SWAAT-Synthetic Sea Water Fog |
X
|
-
|
-
|
-
|
Multi-Test Control Package Required |
| ASTM G 85 A4 Salt Fog/SO2 |
X
|
-
|
-
|
-
|
Multi-Test Control Pkg, Gas Accessory Pkg, Auto Cover Lock |
| ASTM G 85 A5 DEC ("Prohesion") |
-
|
X
|
-
|
-
|
Dilute Electrolyte Cyclic Fog/Dry Test |
| ASTM G 87 Moist SO2 w/Condensing RH - Method A (Kesternich) |
X
|
-
|
-
|
-
|
Multi-Test Control Pkg, Gas Accessory Pkg, Auto Cover Lock |
| British | |||||
| BS AU148 P2 |
X
|
X
|
-
|
-
|
|
| BS 2011 P2.1 |
X
|
X
|
-
|
-
|
|
| BS 3900, F4 (formerly DEF 1053 M24) |
X
|
X
|
-
|
-
|
|
| BS 3900, F9 (formerly DEF 1053 M36) |
|
X
|
-
|
-
|
|
| BS 5466 P1, 2 & 3 |
X
|
X
|
-
|
-
|
|
| BS 7479 |
X
|
X
|
-
|
-
|
|
| BS 7479 AASS |
X
|
-
|
-
|
-
|
|
| BS 7479 CASS |
X
|
-
|
-
|
-
|
|
| DEF 0755 (formerly DEF 133) |
X
|
X
|
-
|
-
|
|
| Chrysler | |||||
| Chrys LP-461-H-15 Salt Fog |
X
|
-
|
-
|
-
|
|
| Chrys LP-461-H-77 Condensing RH |
X
|
-
|
-
|
-
|
w/RH Accessory Package |
| Chrys LP-463-PB9-01 Non-Condensing, Fogging RH |
X
|
-
|
-
|
-
|
|
| Chrys LP-463-PB45-01 |
-
|
-
|
X
|
-
|
|
| Chrys PF-4008 Par 2.6.2 Dust |
-
|
-
|
-
|
X
|
|
| French | |||||
| CCT U0101 A |
X
|
X
|
-
|
-
|
|
| NFX 41-002 |
X
|
X
|
-
|
-
|
|
| German | |||||
| BMW CCT |
-
|
X
|
-
|
-
|
|
| DIN 50907 |
-
|
X
|
-
|
-
|
|
| DIN 50017 Condensing RH |
X
|
-
|
-
|
-
|
Multi-Test Control Package Required |
| DIN 50018 Moist SO2 |
X
|
-
|
-
|
-
|
Multi-Test Control Pkg, Gas Accessory Pkg, Auto Cover Lock |
| DIN 50021 Salt Fog |
X
|
X
|
-
|
-
|
|
| VG 95210 |
X
|
X
|
-
|
-
|
|
| VG 95332 |
X
|
X
|
-
|
-
|
|
| U.S. Government | |||||
| Fed 791C Method 4001.3 |
X
|
X
|
-
|
-
|
|
| Ford | |||||
| Ford B1-104-01 |
-
|
-
|
X
|
-
|
|
| Ford BJ7-2 Salt Fog |
X
|
X
|
-
|
-
|
|
| Ford BQ5-1 CASS-Copper Accelerated Salt Fog |
X
|
-
|
-
|
-
|
|
| Ford BQ4-2 Fogging RH |
X
|
X
|
-
|
-
|
|
| Ford BT2-1 Condensing RH |
X
|
-
|
-
|
-
|
w/RH Accessory Package |
| Ford CETP: 00.00-L-467 Laboratory Accelerated Cyclic Corrosion Test |
-
|
X
|
-
|
-
|
|
| General Motors | |||||
| GMW3172 Salt Fog |
-
|
X
|
-
|
-
|
|
| GMW3286 Salt Fog |
X
|
X
|
-
|
-
|
Formerly GM 4298P - Data Recorder Recommended |
| GM 4465P Fogging RH |
X
|
X
|
-
|
-
|
Data Recorder Required |
| GM 4466P Acetic Acid Salt Fog |
X
|
-
|
-
|
-
|
|
| GM 4476P CASS-Copper Accelerated Salt Fog |
X
|
-
|
-
|
-
|
w/Cass Solution Valve |
| GM 9103P Fogging RH |
X
|
-
|
-
|
X
|
Several Test Methods at once |
| GM 9110P Fogging RH |
X
|
-
|
-
|
X
|
Several Test Methods at once |
| GM 9505P Fogging RH SCAB Test |
X
|
-
|
-
|
X
|
Several Test Methods at once |
| GM 9540P Cyclic Accelerated Corrosion Test |
-
|
X
|
-
|
-
|
see GMW14872 |
| GM 14872 Cyclic Accelerated Corrosion Test |
-
|
X
|
-
|
-
|
|
| Industry | |||||
| Simulated Acid Rain (SART) |
X
|
X
|
-
|
-
|
|
| Synthetic Sweat |
X
|
X
|
-
|
-
|
|
| International Standards Organization | |||||
| ISO 3231 |
X
|
- |
-
|
-
|
Multi-Test Control Pkg, Gas Accessory Pkg, Auto Cover Lock |
| ISO 7253 |
X
|
X
|
-
|
-
|
|
| ISO 9227 Salt Fog |
X
|
X
|
-
|
-
|
|
| ISO 9227 Acetic Acid Salt Fog |
X
|
-
|
-
|
-
|
|
| ISO 9227 CASS-Copper Accelerated Salt Fog |
X
|
-
|
-
|
-
|
|
| Japanese | |||||
| JIS D 5500 Dust |
-
|
-
|
-
|
X
|
|
| JIS Z 2371 Salt Fog |
X
|
X
|
-
|
X
|
Data Recorder Required |
| Japan Acid Rain CCT |
-
|
X
|
-
|
-
|
|
| Komatsu KES 06.790.3 Salt Fog |
X
|
X
|
-
|
-
|
|
| Mazda MCT-1M Cyclic Cosmetic Corrosion Test |
-
|
X
|
-
|
-
|
Data Recorder Required |
| Mazda MCT-2M Cyclic Perforation Corrosion Test |
-
|
X
|
-
|
-
|
Data Recorder Required |
| Nissan CCT I Cyclic Perforation Corrosion Test |
-
|
X
|
-
|
-
|
|
| Nissan CCT II |
-
|
X
|
-
|
-
|
|
| Nissan CCT IV Cyclic Cosmetic Corrosion Test |
-
|
X
|
-
|
-
|
|
| Nissan CCT V |
-
|
X
|
-
|
-
|
|
| Nissan NES M140 |
X
|
X
|
-
|
-
|
|
| U.S. Military | |||||
| Mil Std 202-Method 101 Salt Fog |
X
|
X
|
-
|
-
|
|
| Mil Std 810 Method 509 Salt Fog |
X
|
X
|
-
|
-
|
|
| Mil Std 883 Method 1009 Salt Fog |
X
|
X
|
-
|
-
|
|
| Mil Std 1344 A Method 1000 Salt Fog |
X
|
X
|
-
|
-
|
|
| Naval Air Development Center | |||||
| NADC 77252-30 Salt Fog/SO2 |
X
|
-
|
-
|
-
|
Multi-Test Control Pkg, Gas Accessory Pkg, Auto Cover Lock |
| Society of Automotive Engineers | |||||
| SAE J 575 3.3 Dust |
-
|
-
|
-
|
X
|
|
| SAE J 575 3.4 |
X
|
X
|
-
|
-
|
|
| SAE J 1563 |
-
|
X
|
-
|
-
|
|
| SAE J 2334 Cyclic Accelerated Corrosion Test |
-
|
X
|
-
|
-
|
|
| Underwriters Laboratories | |||||
| UL 199 Par 35.6 |
X
|
X
|
-
|
-
|
|